Firmware Versions on the Celestron CGE Series

Celestron CGE scopes have two sets of processors. There are processors in the hand control (HC) and there are processors in the base of the scope in a section known as the motor control (MC). The MC firmware can be updated by the owner (read this).   Hand controls prior to version 4 can NOT be updated, but if you have a version 4 hand control (owners of older versions read this for info on purchasing the upgradeable hand control), the firmware can be updated (read this).

For additional details about features on newer versions, check the Manuals section of this web site.

Please email me if you have a scope with different versions than listed here.

HC Versions

  • 4.13 - This version allows the motor control (MC) firmware to be upgraded via the port on the bottom of the hand control.
  • 4.12 - The most significant change in this version is variable brightness control for the display and buttons - values are from 0 (off) to 8 (full brightness).  There is also a fix that reduces (but does not eliminate) the chance that the display comes up blank the first time you power up, a problem much more prevalent in cold weather.  The fix on those occasions when it does still come up blank remains the same - turn off the power, wait a couple of seconds and turn on the power again.  The Version menu item has been changed - it now displays the mount model after displaying the HC and MC versions.
  • 4.10 - The most significant change in this version is Sync and multiple mount calibration stars.  Sync is available both via the hand control and via PC software (TheSky, Starry Night, etc.).  This provides very accurate GoTo pointing in the area of the sky where the Sync is performed and it allows the PC software to match with the actual position the scope is pointed to.  Multiple mount calibration stars take the place of the previous use of one calibration star for determining cone error and the Dec switch/index mark offset resulting in much improved pointing accuracy.  Other new features:  a display of the polar alignment error, Solar System Align routine, the Sun is now available as a GoTo and alignment object, "RA" and "Dec" are used in most places in the menus rather than "Alt" and "Azm", and the new ability to start PEC playback and proceed with normal use of the hand control.
  • 3.01 -  Original version on the CGE mount.
  • 3.0 - A version which seemed to have leaked out on accident - thus far seen on only one scope.  Differences between this and 3.0 seem to be minor.  This version may be slightly less accurate during the Polar Alignment routine, the Dec Switch calibration value may occasionally display incorrectly and the Version command on the menu will display the minor version of the MC firmware with only one digit instead of two - in other words, 5.06 will be displayed as 5.6.

MC Versions

  • 5.14 - Corrects a potential problem with the cordwrap prevention feature.
  • 5.07 - An official version.  Rate 1 is now 50% of sidereal while rate 2 is 100% of sidereal.  This is the first version to support Celestron's free PECTool utility.
  • 5.06 - An official (non-beta) version available for download from Celestron.  Improved anti-backlash, improved PEC performance, slight improvement on sidereal tracking rate.
  • 41.36 - This is a beta (test) version.  Improves PEC performance.
  • 5.05 - Reportedly fixed autoguider problems including runaway slew when autoguiding.  Also reportedly fixed occasional runaway slew during regular GoTo operations.  That said, it is believed these problems were not actually fixed until version 41.36 .
  • 40.43 - This is a beta (test) version which probably became official version 5.05.  It was available for a short period of time on the Celestron web site and was removed when 5.05 was released.
  • 5.02 - Original version on the CGE mount.
  • 5.0 - A version which seemed to have leaked out on accident - thus far seen on only one scope.  It is definitely recommended the mount be updated to the latest MC firmware.

Determining Versions

Use the Version option on the Utility menu.